New Original KEYENCE FD-MZ100ATKP Non-Wetted Electrode Electromagnetic Flow Sensor

Model FD-MZ100ATKP
Type Vertical
Shape Built-in amplifier
Rated flow range 1.4 – 26.0 G/min (5.0 – 100 L/min)
Possible display range 1.4 – 52.8 G/min (5.0 – 200 L/min)*2
Possible ranges to set 0 – 52.8 G/min (0 – 200 L/min)
Connection port NPT1 (25 A)
Detectable fluids Water or non-corrosive liquid
Conductivity of detection fluids 5 µS/cm or higher

New Original KEYENCE FD-Q20C Clamp-on Flow Sensor

Model FD-Q20C
Supported pipe diameter 1/2″ (15 A), ø18 to ø23 (mm)
3/4″ (20 A), ø23 to ø28 (mm)
Supported pipe materials Metal pipe/Resin pipe*1
Supported fluids Various liquid [i.e. water (including DI), oils, chemicals, etc.]
Supported fluid temperature 0 to 85°C 32 to 185°F (No freezing on the pipe surface)
Maximum rated flow 1/2″ (15 A): 60 L/min, 15.9 G/min
3/4″ (20 A): 100 L/min, 26.4 G/min
Zero cut flow rate 2.5 L/min (Default)
Display method Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

New Original KEYENCE GA-245 Shock Sensor

Model GA-245
Type AC adj-dial
Applicable sensor head GH-313A, GH-513/613
Sensitivity adjustment 10-turn potentiometer dial
Response frequency 40 Hz to 8 kHz (-3dB)
Minimum detectable acceleration 0.98 m/s2 (GH-313A)
Indicator lamp Power indicator, 4 vibration level indicators
Output Control output Solid-state NPN: 100 mA 40 V max.*1
Relay SPDT, 250 VAC, 2A (resistive load)
Analog 0 to 20 VAC (P-P), 0 to 10 VDC (switch-selectable)
Output delay time Solid-state: 1 ms, Relay: 10 ms

New Original KEYENCE EX-V02 High-speed High-Accuracy Digital Displacement Inductive Sensor

Model EX-V02
Type Amplifier Unit NPN
Shape M10 x 18 mm 0.71″ Threaded
Measuring range 0 to 2 mm 0.08″
Display range -19,999 to +19,999
Linearity ±0.3% of F.S.
Resolution (No. of averaging
measurements: 64)
0.4 μm
Sampling rate 40,000 samplings max./sec.

New Original KEYENCE FW-H07 High Power Digital Ultrasonic Sensor

Model FW-H07
Type Standard type
Detecting area 150 to 700 mm 5.9″ to 27.6″
Response speed 300 ms
Temperature characteristics 0.25% of F.S./°C
Indicator lamp Operation indicator (orange) x1 (Turns on when the power is turned on.)
Dimensions M18 x P1, Length= 63.5 mm 2.50″

New Original KEYENCE IB-30 Thrubeam Type Laser Detection Sensor

Model IB-30
Light source Wavelength 660 nm (Visible light semiconductor laser)
Laser Class Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10)
Installation distance 0 to 300 mm 11.81″
Measurement range 30 mm 1.18″
Sampling cycle 12,500 times/sec. (80 µs)
Minimum detection target ø0.2 mm ø0.01″
Repeatability 10 µm 0.39 Mil
Temperature characteristics ±0.1 % of F.S./°C (±30 µm 1.18 Mil)
Operating indicators Laser emission warning indicator: green LED

New Original KEYENCE IG-028 Multi-Purpose CCD Laser Micrometer

Model IG-028
Operation principle CCD method
Light source Wavelength 660 nm (Visible light semiconductor laser)
FDA Class 1
IEC/JIS Class 1
Mounting distance 0 to 1500 mm 59.06″
Measurement range 28 mm 1.10″
Sampling cycle 980 µs (When the number of times for averaging is set to [hsp]: 490 µs)
Minimum detectable object High sensitivity mode ø0.1 mm ø0.003″ (Setting distance: 100 mm 3.94″)
Standard mode ø0.2 mm ø0.007″ (Setting distance: 50 mm 1.97″ or less),
ø0.5 mm ø0.02″ (Setting distance: 500 mm 19.68″)*2

New Original KEYENCE IL-1000 CMOS Multi-Function Analog Laser Sensor

Model IL-1000
Type DIN-rail mount
Main unit/Expansion unit Main unit
Head compatibility Compatible
Display Minimum
displayable unit
IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm, IL-2000: 100 µm
Display range IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable),
IL-2000: ±9999.9 mm to ±9999 mm (2 levels selectable)
Display rate Approx. 10 times/sec.
Analog voltage output ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω
Analog current output 4 to 20 mA Maximum load resistance of 350 Ω

New Original KEYENCE IX-150 Image-Based Laser Sensor

Model IX-150
Reference distance 150 mm 5.91″
Measuring distance 100 to 200 mm 3.94″ to 7.87″
Detection area Scan mode Measuring distance of 100 mm 3.94″: 56.5 × 42.0 mm 2.22″ × 1.65″
Measuring distance of 150 mm 5.91″: 82.5 × 61.5 mm 3.25″ × 2.42″
Measuring distance of 200 mm 7.87″: 108.5 × 81.0 mm 4.27″ × 3.19″
(X direction) × (Y direction)
Line mode Measuring distance of 100 mm 3.94″: 56.5 mm 2.22″
Measuring distance of 150 mm 5.91″: 82.5 mm 3.25″
Measuring distance of 200 mm 7.87″: 108.5 mm 4.27″(X direction)

New Original KEYENCE GT-72A General Purpose Digital Contact Sensor

Model GT-72A
Type Amplifier unit
Mounting method DIN rail mount
Output NPN output
Main unit/expansion unit Expansion unit
Power consumption Normal At 12 V: 1,140 mW (95 mA) or less, At 24 V: 1,200 mW (50 mA) or less
Power saving (Eco) At 12 V: 600 mW (50 mA) or less, At 24 V: 840 mW (35 mA) or less
Display power Measured value display 6-digit 7-segment LED (red)
Other displays 2-color 13-level bar LED display (red, green), indicators (red, green)

New Original KEYENCE GT2-75P High-Accuracy Digital Contact Sensor

Model GT2-75P
Mounting method Panel mount
Output PNP output
Main unit/expansion unit Main unit
Power supply voltage 10 to 30 VDC, including 10 % ripple (P-P), Class 2
Power consumption Normal 2,200 mW max. (30 V, 73.3 mA max.)
Power saving (Eco) 1,700 mW max. (30 V, 56.7 mA max.)
Display power Measured value display 6 + 1/2-digit 7-segment LED (red)
Other displays 2-color, 13-level bar LED display (red, green), indicators (red, green)

New Original KEYENCE GT2-PA12K High-Accuracy Digital Contact Sensor

Model GT2-PA12K
Detection system Scale Shot System II, absolute (no tracking errors) type
Measuring range 12 mm 0.47″
Resolution 0.1 µm 0.004 Mil
Indicated accuracy 1 µm 0.04 Mil (p-p)
Measuring force Downward mounting 1.2 N
Side mounting 1.15 N
Upward mounting 1.1 N
Sampling cycle 4 ms
Fluid used Clean dry air