Productos
New Original KEYENCE FD-MZ100ATKP Non-Wetted Electrode Electromagnetic Flow Sensor
| Model | FD-MZ100ATKP | |||
| Type | Vertical | |||
| Shape | Built-in amplifier | |||
| Rated flow range | 1.4 – 26.0 G/min (5.0 – 100 L/min) | |||
| Possible display range | 1.4 – 52.8 G/min (5.0 – 200 L/min)*2 | |||
| Possible ranges to set | 0 – 52.8 G/min (0 – 200 L/min) | |||
| Connection port | NPT1 (25 A) | |||
| Detectable fluids | Water or non-corrosive liquid | |||
| Conductivity of detection fluids | 5 µS/cm or higher | |||
New Original KEYENCE FD-Q20C Clamp-on Flow Sensor
| Model | FD-Q20C | |||
| Supported pipe diameter | 1/2″ (15 A), ø18 to ø23 (mm) 3/4″ (20 A), ø23 to ø28 (mm) |
|||
| Supported pipe materials | Metal pipe/Resin pipe*1 | |||
| Supported fluids | Various liquid [i.e. water (including DI), oils, chemicals, etc.] | |||
| Supported fluid temperature | 0 to 85°C 32 to 185°F (No freezing on the pipe surface) | |||
| Maximum rated flow | 1/2″ (15 A): 60 L/min, 15.9 G/min 3/4″ (20 A): 100 L/min, 26.4 G/min |
|||
| Zero cut flow rate | 2.5 L/min (Default) | |||
| Display method | Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator | |||
New Original KEYENCE GA-245 Shock Sensor
| Model | GA-245 | |||
| Type | AC adj-dial | |||
| Applicable sensor head | GH-313A, GH-513/613 | |||
| Sensitivity adjustment | 10-turn potentiometer dial | |||
| Response frequency | 40 Hz to 8 kHz (-3dB) | |||
| Minimum detectable acceleration | 0.98 m/s2 (GH-313A) | |||
| Indicator lamp | Power indicator, 4 vibration level indicators | |||
| Output | Control output | Solid-state | NPN: 100 mA 40 V max.*1 | |
| Relay | SPDT, 250 VAC, 2A (resistive load) | |||
| Analog | 0 to 20 VAC (P-P), 0 to 10 VDC (switch-selectable) | |||
| Output delay time | Solid-state: 1 ms, Relay: 10 ms | |||
New Original KEYENCE EX-V02 High-speed High-Accuracy Digital Displacement Inductive Sensor
| Model | EX-V02 | |||
| Type | Amplifier Unit NPN | |||
| Shape | M10 x 18 mm 0.71″ Threaded | |||
| Measuring range | 0 to 2 mm 0.08″ | |||
| Display range | -19,999 to +19,999 | |||
| Linearity | ±0.3% of F.S. | |||
| Resolution (No. of averaging measurements: 64) |
0.4 μm | |||
| Sampling rate | 40,000 samplings max./sec. | |||
New Original KEYENCE FW-H07 High Power Digital Ultrasonic Sensor
| Model | FW-H07 | |||
| Type | Standard type | |||
| Detecting area | 150 to 700 mm 5.9″ to 27.6″ | |||
| Response speed | 300 ms | |||
| Temperature characteristics | 0.25% of F.S./°C | |||
| Indicator lamp | Operation indicator (orange) x1 (Turns on when the power is turned on.) | |||
| Dimensions | M18 x P1, Length= 63.5 mm 2.50″ | |||
New Original KEYENCE IB-30 Thrubeam Type Laser Detection Sensor
| Model | IB-30 | |||
| Light source | Wavelength | 660 nm (Visible light semiconductor laser) | ||
| Laser Class | Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10) | |||
| Installation distance | 0 to 300 mm 11.81″ | |||
| Measurement range | 30 mm 1.18″ | |||
| Sampling cycle | 12,500 times/sec. (80 µs) | |||
| Minimum detection target | ø0.2 mm ø0.01″ | |||
| Repeatability | 10 µm 0.39 Mil | |||
| Temperature characteristics | ±0.1 % of F.S./°C (±30 µm 1.18 Mil) | |||
| Operating indicators | Laser emission warning indicator: green LED | |||
New Original KEYENCE IG-028 Multi-Purpose CCD Laser Micrometer
| Model | IG-028 | |||
| Operation principle | CCD method | |||
| Light source | Wavelength | 660 nm (Visible light semiconductor laser) | ||
| FDA | Class 1 | |||
| IEC/JIS | Class 1 | |||
| Mounting distance | 0 to 1500 mm 59.06″ | |||
| Measurement range | 28 mm 1.10″ | |||
| Sampling cycle | 980 µs (When the number of times for averaging is set to [hsp]: 490 µs) | |||
| Minimum detectable object | High sensitivity mode | ø0.1 mm ø0.003″ (Setting distance: 100 mm 3.94″) | ||
| Standard mode | ø0.2 mm ø0.007″ (Setting distance: 50 mm 1.97″ or less), ø0.5 mm ø0.02″ (Setting distance: 500 mm 19.68″)*2 |
|||
New Original KEYENCE IL-1000 CMOS Multi-Function Analog Laser Sensor
| Model | IL-1000 | |||
| Type | DIN-rail mount | |||
| Main unit/Expansion unit | Main unit | |||
| Head compatibility | Compatible | |||
| Display | Minimum displayable unit |
IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm, IL-2000: 100 µm | ||
| Display range | IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable), IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable), IL-2000: ±9999.9 mm to ±9999 mm (2 levels selectable) |
|||
| Display rate | Approx. 10 times/sec. | |||
| Analog voltage output | ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω | |||
| Analog current output | 4 to 20 mA Maximum load resistance of 350 Ω | |||
New Original KEYENCE IX-150 Image-Based Laser Sensor
| Model | IX-150 | |||
| Reference distance | 150 mm 5.91″ | |||
| Measuring distance | 100 to 200 mm 3.94″ to 7.87″ | |||
| Detection area | Scan mode | Measuring distance of 100 mm 3.94″: 56.5 × 42.0 mm 2.22″ × 1.65″ Measuring distance of 150 mm 5.91″: 82.5 × 61.5 mm 3.25″ × 2.42″ Measuring distance of 200 mm 7.87″: 108.5 × 81.0 mm 4.27″ × 3.19″ (X direction) × (Y direction) |
||
| Line mode | Measuring distance of 100 mm 3.94″: 56.5 mm 2.22″ Measuring distance of 150 mm 5.91″: 82.5 mm 3.25″ Measuring distance of 200 mm 7.87″: 108.5 mm 4.27″(X direction) |
|||
New Original KEYENCE GT-72A General Purpose Digital Contact Sensor
| Model | GT-72A | |||
| Type | Amplifier unit | |||
| Mounting method | DIN rail mount | |||
| Output | NPN output | |||
| Main unit/expansion unit | Expansion unit | |||
| Power consumption | Normal | At 12 V: 1,140 mW (95 mA) or less, At 24 V: 1,200 mW (50 mA) or less | ||
| Power saving (Eco) | At 12 V: 600 mW (50 mA) or less, At 24 V: 840 mW (35 mA) or less | |||
| Display power | Measured value display | 6-digit 7-segment LED (red) | ||
| Other displays | 2-color 13-level bar LED display (red, green), indicators (red, green) | |||
New Original KEYENCE GT2-75P High-Accuracy Digital Contact Sensor
| Model | GT2-75P | |||
| Mounting method | Panel mount | |||
| Output | PNP output | |||
| Main unit/expansion unit | Main unit | |||
| Power supply voltage | 10 to 30 VDC, including 10 % ripple (P-P), Class 2 | |||
| Power consumption | Normal | 2,200 mW max. (30 V, 73.3 mA max.) | ||
| Power saving (Eco) | 1,700 mW max. (30 V, 56.7 mA max.) | |||
| Display power | Measured value display | 6 + 1/2-digit 7-segment LED (red) | ||
| Other displays | 2-color, 13-level bar LED display (red, green), indicators (red, green) | |||
New Original KEYENCE GT2-PA12K High-Accuracy Digital Contact Sensor
| Model | GT2-PA12K | |||
| Detection system | Scale Shot System II, absolute (no tracking errors) type | |||
| Measuring range | 12 mm 0.47″ | |||
| Resolution | 0.1 µm 0.004 Mil | |||
| Indicated accuracy | 1 µm 0.04 Mil (p-p) | |||
| Measuring force | Downward mounting | 1.2 N | ||
| Side mounting | 1.15 N | |||
| Upward mounting | 1.1 N | |||
| Sampling cycle | 4 ms | |||
| Fluid used | Clean dry air | |||