New Original Phoenix Contact 1507764 SACC‑M12MSB‑5CON‑PG9‑SH‑AU M12 Male 5‑Pin Connector
"*" señala los campos obligatorios
New Original Phoenix Contact 1507764 SACC‑M12MSB‑5CON‑PG9‑SH‑AU M12 Male 5‑Pin Connector
Product Overview
Phoenix Contact SACC‑M12MSB‑5CON‑PG9‑SH‑AU, part number 1507764, is a brand‑new original field‑wireable straight M12 male circular connector from the SACC series. This B‑coded, shielded 5‑pin plug adopts screw‑terminal wiring technology and PG9 cable gland, designed for PROFIBUS‑DP field‑bus communication in industrial automation systems. It enables on‑site cable assembly without special crimping tools, widely used for connecting field sensors, actuators, bus nodes and industrial controllers. Marked as “New Original”, it represents genuine factory‑produced component with full‑factory performance testing, intact gold‑plated contacts and complete sealing parts, free of refurbished or second‑hand products. It provides stable shielded data transmission for factory floor equipment under harsh workshop conditionsmedia.digi….
Main Functions
- Field‑assembly bus connection: Straight M12 male plug for on‑site termination of PROFIBUS‑DP cables by screw terminals.
- Full‑shielded signal transmission: Integrated shielding structure suppresses electromagnetic interference for field‑bus communication.
- PG9 cable strain relief: PG9 cable gland provides reliable cable clamping and strain relief for outer cable diameters 6‑8.5 mm.
- Screw‑type contact termination: Supports both solid and stranded conductors with or without wire ferrules.
- IP67 environmental protection: Delivers dust‑proof and water‑proof performance for cabinet‑outside field‑device wiring.
- Anti‑mis‑mating B‑coding: B‑code mechanical key prevents mismating with A‑coded / D‑coded M12 connectors.
- Metal knurl locking nut: Nickel‑plated metal knurl for stable threaded locking with defined tightening torque.
- High mechanical durability: Supports at least 100 mating‑unmating cycles for long‑term industrial usage.
Technical Characteristics
- Complies with IEC 61076‑2‑101 M12 circular connector industrial standard.
- Gold‑plated brass contacts guarantee low contact resistance and anti‑oxidation performance.
- Connector housing: zinc die‑cast nickel‑plated grip body, PA66 contact carrier, NBR sealing rings.
- Screw‑clamp wiring, no crimp tool required for field installation.
- Complete shielding continuity for PROFIBUS‑DP bus cable shielding layer.
- Pollution degree 3, over‑voltage category II for industrial control environment.
- RoHS‑compliant construction material, UL 94‑HB flame‑retardant grade.
- IP67 protection rating when properly mated and assembled with qualified cables.
Core Technical Parameters
| Item | Parameter Value |
|---|---|
| Part Number | 1507764 SACC‑M12MSB‑5CON‑PG9‑SH‑AU |
| Connector Type | M12 straight male field‑wireable plug |
| Coding | B‑coded (for PROFIBUS‑DP) |
| Number of Contacts | 5 pins |
| Termination Method | Screw terminal connection |
| Rated Current | 4 A |
| Rated Voltage | 48 V AC / 60 V DC |
| Conductor Cross‑section | 0.25‑0.75 mm² solid; 0.14‑0.75 mm² stranded with ferrule |
| AWG Range | 24‑18 AWG |
| Cable Outer Diameter | 6 mm … 8.5 mm (PG9 gland) |
| Contact Resistance | ≤ 3 mΩ |
| Insulation Resistance | ≥ 100 MΩ |
| Ambient Operating Temperature | ‑40 °C ~ +85 °C |
| Protection Class | IP67 (mated condition) |
| Mating Cycles | ≥ 100 cycles |
| Weight | 75 g |
| Recommended Tightening Torque | M12 knurl: 0.4 Nm; screw terminal:0.2 Nm |
Product Dimensions
All dimension values are given in millimetres.
- Overall total length: 62 mm
- Max outer diameter of grip housing: 20 mm
- M12 thread length: 12 mm
- PG9 cable‑gland outer diameter: 18 mm
- Required wire stripping length: 5 mm
Note: Apply correct tightening torque during assembly. Improper torque may cause bad contact or seal failure. Only IP67‑rated performance is achieved after full mating and proper cable‑gland tightening.
10 Phoenix Contact Similar‑function SACC‑series M12 Field‑wireable Connectors
Below are ten original Phoenix Contact M12 field‑assembly circular connectors, covering male / female, different coding types and pin counts for automation signal and bus wiring:
- SACC‑M12FSB‑5CON‑PG9‑SH‑AU (1507777): 5‑pin B‑coded shielded female M12 plug for PROFIBUS‑DP bus cable terminationmedia.digi….
- SACC‑M12MS‑5CON‑PG9‑SH (1694266): 5‑pin A‑coded shielded male M12 plug for sensor‑actuator signal wiring.
- SACC‑M12FS‑5CON‑PG9‑SH (1694279): 5‑pin A‑coded shielded female M12 field‑wireable plug.
- SACC‑M12MSB‑4CON‑PG9‑SH‑AU (1507761): 4‑pin B‑coded shielded male M12 plug for PROFIBUS‑DP.
- SACC‑M12FSB‑4CON‑PG9‑SH‑AU (1507774): 4‑pin B‑coded shielded female M12 bus plug.
- SACC‑M12MS‑8CON‑PG9‑SH (1694282): 8‑pin A‑coded shielded male M12 plug for multi‑signal sensors.
- SACC‑M12FS‑8CON‑PG9‑SH (1694295): 8‑pin A‑coded shielded female M12 field‑assembly connector.
- SACC‑M12MS‑12CON‑PG9‑SH (1694308): 12‑pin A‑coded shielded male M12 high‑pin‑count plug.
- SACC‑M12MSB‑5CON‑PG11‑SH‑AU (1507766): 5‑pin B‑coded male M12 plug with PG11 gland for thicker bus cables.
- SACC‑M12FSB‑5CON‑PG11‑SH‑AU (1507780): 5‑pin B‑coded female M12 plug with PG11 cable‑gland.