Keyence
New Original KEYENCE IV3-G500MA Vision Sensor with Built-in AI
| Model | IV3-G500MA | |||
| Type | Standard | |||
| Installed distance | 50 mm 1.97″ or more | |||
| Field of view | Installed distance 50 mm 1.97″: 22 (H) × 16 (V) mm 0.87″ (H) × 0.63″ (V) Installed distance 3000 mm 118.11″: 1184 (H) × 888 (V) mm 46.61″ (H) × 34.96″ (V) (typical example) |
|||
| Image receiving element | Type | 1/2.9 inch monochrome CMOS | ||
| Number of pixels | 1280 (H) × 960 (V) | |||
| Focus adjustment | Auto | |||
| Exposure time | 12 μs to 9 ms | |||
New Original KEYENCE IV2-G500CA Vision Sensor with Built-in AI
| Model | IV2-G500CA | |||
| Type | Standard model | |||
| Reference distance | 20 to 500 mm 0.79″ to 19.69″ | |||
| Field of view | Installation distance of 20 mm 0.79″: 10 (H) × 7.5 (V) mm 0.39″ (H) × 0.30″ (V) to Installation distance of 500 mm 19.69″: 200 (H) × 150 (V) mm 7.87″ (H) × 5.91″ (V) |
|||
| Indicators | 2 (the same display details for both indicators) | |||
| Image receiving element | Type | 1/3 inch color CMOS | ||
| Number of pixels | 752 (H) × 480 (V) | |||
| Focus adjustment | Automatic | |||
| Exposure time | 1/10 to 1/50000 | |||
New Original KEYENCE IV-500MA Vision Sensor
| Model | IV-500MA | |||
| Type | Standard distance | |||
| Installed distance | 50 to 500 mm 1.97″ to 19.69″ | |||
| View | Installed distance 50 mm 1.97″: 25 (H) x 18 (V) mm 0.98″ (H) x 0.71″(V) to installed distance 500 mm 19.69″: 210 (H) x 157 (V) mm 8.27″ (H) x 6.18″ (V) |
|||
| Image sensor | Type | 1/3 inch monochrome CMOS | ||
| Pixel | 752 (H) x 480 (V) 29.61″ (H) x 18.90″ (V) | |||
| Focus adjustment | Auto | |||
| Exposure time | 1/10 to 1/25,000 | |||
New Original KEYENCE CA-LH16 Lenses for Machine Vision
| Model | CA-LH16 | |||
| Focal point | 16 mm 0.63″ | |||
| F-stop range (aperture) | F1.4 to F16 | |||
| Minimum WD | 0.2 m 0.7′ | |||
| Mount | C-mount | |||
| Filter size | 25.5 mm 1.00″ P0.5 | |||
| Compatible image sensor size | 2/3″ | |||
| TV distortion | -0.05 % (-0.1 %) | |||
| Resolving power | 100 cycles/mm at center, 80 cycles/mm on periphery | |||
| Ambient temperature/humidity range | 0 to +50°C 32 to 122°F, 80% RH or less (No condensation) | |||
| Weight | Approx. 81 g | |||
New Original KEYENCE TM-3001 High Speed 2D Optical Micrometer Controller
| Model | TM-3001 | |||
| Head compatibility | Compatible | |||
| Number of connectable sensors | 2 units max. | |||
| Display | Minimum display unit | 0.01 µm, 0.001 mm2, 0.01 ° | ||
| Maximum display range | ±9999.99 mm ±393.7″, ±99999.9 mm2, ±99999.9° | |||
| Input terminal block | Laser remote interlock input | Non-voltage input*2 | ||
| Trigger input (for Head A) | ||||
| Timing 1 input | ||||
| Auto-zero 1 input | ||||
| Reset input | ||||
| Output terminal block | Analog voltage output | ±10 V x 2 outputs, out put impedance: 100 Ω | ||
New Original KEYENCE LS-7001 High-speed High-accuracy Digital Micrometer
| Model | LS-7001 | |||
| Type | Standard | |||
| No. of connectable sensor heads | 2 (fully compatible for all head types except monitor (M) models) | |||
| Display | Measurement display | Main display: 7-segment red LED (Character height: 20.3 mm 0.80″) Sub-display: 7-segment red LED (Character height: 9.9 mm 0.39″) x 3 |
||
| Minimum display unit | 0.01 µm to 100 µm (7-level selectable) | |||
| Display range | ±99.99999 to ±9,999.9 mm ±3.937″ to ±393.7″ (Linked to minimum display unit setting, mm/µm selectable) | |||
| Measurement position monitor | 7-level display with a red LED | |||
| Tolerance check output display | Green LED (GO), Red LED x 2 (HI, LO) | |||
New Original KEYENCE LJ-X8000A High Resolution Inline Measurement Sensor
| Model | LJ-X8000A | |||
| Head input | Up to 1 head Compatible with LJ-X8000 series heads and LJ-V7000 series heads |
|||
| Sampling cycle (trigger interval) | When connecting the LJ-X8000 Series: maximum speed of 16 kHz (63 μs) When connecting the LJ-V7000 Series: maximum speed of 64 kHz (16 μs) (Luminance output types for model designations ending with B have a maximum speed of 8 kHz (125 μs)) |
|||
| Interface | Control input | Supports the batch measurement start (MEASURE_START) and batch measurement stop (MEASURE_STOP). | ||
| Control output | •Supports the trigger ready (READY) and system error (ERROR). •Photo MOSFET |
|||
| Synchronous input / output | For trigger synchronization of multiple controllers | |||
| Ethernet | Supports the profile output, setting, controll, 1000BASE-T/100BASE-TX | |||
New Original KEYENCE LK-G3001 High-Speed Digital Micrometer Controller
| Model | LK-G3001 | |||
| Type | Separate monitor model | |||
| Display | Head compatibility | All LK-G sensor heads are compatible | ||
| Number of connectable sensors | Maximum of 2 units | |||
| Minimum display unit | 0.01 µm | |||
| Display range | ±9,999.99 mm to ±9,999.99 µm (Selectable from six levels) | |||
| Refresh rate | 10 times/sec | |||
| Terminal block | Analog voltage output | ±10 V x 2 outputs, output impedance: 100 Ω | ||
| Analog current output | 4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω | |||
| Timing input | For OUT1, non-voltage input | |||
| Reset input | ||||
| Auto-zero input | ||||
| Laser remote interlock input | Non-voltage input | |||
| Comparator output | For OUT1, NPN open-collector output | |||
| Alarm output | For OUT1, NPN open-collector output (N.C.) | |||
New Original KEYENCE CL-3000 Confocal Displacement Sensor
| Model | CL-3000 | |||
| Type | Controller | |||
| Number of optical unit connections | Controller only: 2 units; using expansion units / relay units: 6 units | |||
| Interface | EtherNet/IP™ | Supports cyclic communication and message communication; RPI: 1 to 10,000 ms (0.5 ms units) Maximum number of connections: 8, complies with Version CT14 conformance test Cannot be used when using PROFINET, PLC link or EtherCAT |
||
| PROFINET | Compatible with conformance class A. Cannot be used when using EtherNet/IP™, PLC link or EtherCAT | |||
| PLC-Link | The following PLCs are supported: Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series Cannot be used when using EtherNet/IP™, PROFINET or EtherCAT |
|||
| Ethernet | Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs 100Base-TX, capable of communication with CL-NavigatorN |
|||
| USB | Conforms to USB 2.0 HighSpeed, capable of communication with CL-NavigatorN | |||
| RS-232C | Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs Baud rate: 9600 to 115,200 bps, data length: 8 bit, stop bit: 1 bit, parity: none / even numbers / odd numbers |
|||
| Terminal (IN) | 13 (supports function switching via software) | |||
| Terminal (OUT) | 11 (supports function switching via software) | |||
New Original KEYENCE SZ-V04 Safety Laser Scanner
| Model | SZ-V04 | |||
| Type | Multi-function Type | |||
| Maximum number of banks | Max. 4 banks | |||
| Multiple scanner heads | Max. 3 scanner heads | |||
| Camera monitoring area | Monitor area: over 190° (-5° to 185°) *8 | |||
| Display | QVGA 2.2inch color LCD | |||
New Original KEYENCE SL-V80HM Light Curtain Safety Sensor
| Model | SL-V80HM | |||
| Detection capability | ø0.98″ ø25 mm | |||
| Beam axis spacing/Lens diameter | 20 mm/ø5 mm 0.79″/ø0.20″ | |||
| Effective aperture angle | Max. ±2.5 ° (When operating distance is 3 m 98.23′ or more) | |||
| Working distance | 0.1 to 7 m | |||
| Response time (ms) | ON→OFF | 16.9 | ||
| OFF→ON | 56.9 | |||
| Light source | Infrared LED (850 nm) | |||
| Operation mode | Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) | |||
New Original KEYENCE PJ-50A Light Curtain Safety Sensor
| Model | PJ-50A | |||
| No. of beam axes | 4 | |||
| Beam axis spacing | 40 mm 1.57″ | |||
| Maximum optical axis number | 28 optical axes (PJ-50A x 1 + PJ-55A x 12) | |||
| Detection area | 120 mm 4.72″ (4 optical axes) to 1080 mm 42.52″ (28 optical axes) | |||
| Detecting distance | 5 m 16.40′ | |||
| Detectable object | Opaque materials (50 mm dia. min.) | |||
| Light source | Infrared LED | |||
| Indicator lamp | Output (PJ-50AR)/Power (PJ-50AT) : Red LED, Stable operation (PJ-50AR) : Green LED | |||
| Response time | 15 ms or less | |||