New Original KEYENCE IV3-G500MA Vision Sensor with Built-in AI

Model IV3-G500MA
Type Standard
Installed distance 50 mm 1.97″ or more
Field of view Installed distance 50 mm 1.97″: 22 (H) × 16 (V) mm 0.87″ (H) × 0.63″ (V)
Installed distance 3000 mm 118.11″: 1184 (H) × 888 (V) mm 46.61″ (H) × 34.96″ (V)
(typical example)
Image receiving element Type 1/2.9 inch monochrome CMOS
Number of pixels 1280 (H) × 960 (V)
Focus adjustment Auto
Exposure time 12 μs to 9 ms

New Original KEYENCE IV2-G500CA Vision Sensor with Built-in AI

Model IV2-G500CA
Type Standard model
Reference distance 20 to 500 mm 0.79″ to 19.69″
Field of view Installation distance of 20 mm 0.79″:
10 (H) × 7.5 (V) mm 0.39″ (H) × 0.30″ (V) to
Installation distance of 500 mm 19.69″:
200 (H) × 150 (V) mm 7.87″ (H) × 5.91″ (V)
Indicators 2 (the same display details for both indicators)
Image receiving element Type 1/3 inch color CMOS
Number of pixels 752 (H) × 480 (V)
Focus adjustment Automatic
Exposure time 1/10 to 1/50000

New Original KEYENCE IV-500MA Vision Sensor

Model IV-500MA
Type Standard distance
Installed distance 50 to 500 mm 1.97″ to 19.69″
View Installed distance 50 mm 1.97″: 25 (H) x 18 (V) mm 0.98″ (H) x 0.71″(V) to
installed distance 500 mm 19.69″: 210 (H) x 157 (V) mm 8.27″ (H) x 6.18″ (V)
Image sensor Type 1/3 inch monochrome CMOS
Pixel 752 (H) x 480 (V) 29.61″ (H) x 18.90″ (V)
Focus adjustment Auto
Exposure time 1/10 to 1/25,000

New Original KEYENCE CA-LH16 Lenses for Machine Vision

Model CA-LH16
Focal point 16 mm 0.63″
F-stop range (aperture) F1.4 to F16
Minimum WD 0.2 m 0.7′
Mount C-mount
Filter size 25.5 mm 1.00″ P0.5
Compatible image sensor size 2/3″
TV distortion -0.05 % (-0.1 %)
Resolving power 100 cycles/mm at center, 80 cycles/mm on periphery
Ambient temperature/humidity range 0 to +50°C 32 to 122°F, 80% RH or less (No condensation)
Weight Approx. 81 g

New Original KEYENCE TM-3001 High Speed 2D Optical Micrometer Controller

Model TM-3001
Head compatibility Compatible
Number of connectable sensors 2 units max.
Display Minimum display unit 0.01 µm, 0.001 mm2, 0.01 °
Maximum display range ±9999.99 mm ±393.7″, ±99999.9 mm2, ±99999.9°
Input terminal block Laser remote interlock input Non-voltage input*2
Trigger input (for Head A)
Timing 1 input
Auto-zero 1 input
Reset input
Output terminal block Analog voltage output ±10 V x 2 outputs, out put impedance: 100 Ω

New Original KEYENCE LS-7001 High-speed High-accuracy Digital Micrometer

Model LS-7001
Type Standard
No. of connectable sensor heads 2 (fully compatible for all head types except monitor (M) models)
Display Measurement display Main display: 7-segment red LED (Character height: 20.3 mm 0.80″)
Sub-display: 7-segment red LED (Character height: 9.9 mm 0.39″) x 3
Minimum display unit 0.01 µm to 100 µm (7-level selectable)
Display range ±99.99999 to ±9,999.9 mm ±3.937″ to ±393.7″ (Linked to minimum display unit setting, mm/µm selectable)
Measurement position monitor 7-level display with a red LED
Tolerance check output display Green LED (GO), Red LED x 2 (HI, LO)

 

New Original KEYENCE LJ-X8000A High Resolution Inline Measurement Sensor

Model LJ-X8000A
Head input Up to 1 head
Compatible with LJ-X8000 series heads and LJ-V7000 series heads
Sampling cycle (trigger interval) When connecting the LJ-X8000 Series: maximum speed of 16 kHz (63 μs)
When connecting the LJ-V7000 Series: maximum speed of 64 kHz (16 μs)
(Luminance output types for model designations ending with B have a maximum speed of 8 kHz (125 μs))
Interface Control input Supports the batch measurement start (MEASURE_START) and batch measurement stop (MEASURE_STOP).
Control output •Supports the trigger ready (READY) and system error (ERROR).
•Photo MOSFET
Synchronous input / output For trigger synchronization of multiple controllers
Ethernet Supports the profile output, setting, controll, 1000BASE-T/100BASE-TX

 

New Original KEYENCE LK-G3001 High-Speed Digital Micrometer Controller

Model LK-G3001
Type Separate monitor model
Display Head compatibility All LK-G sensor heads are compatible
Number of connectable sensors Maximum of 2 units
Minimum display unit 0.01 µm
Display range ±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)
Refresh rate 10 times/sec
Terminal block Analog voltage output ±10 V x 2 outputs, output impedance: 100 Ω
Analog current output 4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω
Timing input For OUT1, non-voltage input
Reset input
Auto-zero input
Laser remote interlock input Non-voltage input
Comparator output For OUT1, NPN open-collector output
Alarm output For OUT1, NPN open-collector output (N.C.)

 

New Original KEYENCE CL-3000 Confocal Displacement Sensor

Model CL-3000
Type Controller
Number of optical unit connections Controller only: 2 units; using expansion units / relay units: 6 units
Interface EtherNet/IP™ Supports cyclic communication and message communication; RPI: 1 to 10,000 ms (0.5 ms units)
Maximum number of connections: 8, complies with Version CT14 conformance test
Cannot be used when using PROFINET, PLC link or EtherCAT
PROFINET Compatible with conformance class A. Cannot be used when using EtherNet/IP™, PLC link or EtherCAT
PLC-Link The following PLCs are supported:
Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
Cannot be used when using EtherNet/IP™, PROFINET or EtherCAT
Ethernet Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs
100Base-TX, capable of communication with CL-NavigatorN
USB Conforms to USB 2.0 HighSpeed, capable of communication with CL-NavigatorN
RS-232C Allows for measurement data output and control I/O via no-protocol command communication with PCs and PLCs
Baud rate: 9600 to 115,200 bps, data length: 8 bit, stop bit: 1 bit, parity: none / even numbers / odd numbers
Terminal (IN) 13 (supports function switching via software)
Terminal (OUT) 11 (supports function switching via software)

 

New Original KEYENCE SZ-V04 Safety Laser Scanner

Model SZ-V04
Type Multi-function Type
Maximum number of banks Max. 4 banks
Multiple scanner heads Max. 3 scanner heads
Camera monitoring area Monitor area: over 190° (-5° to 185°) *8
Display QVGA 2.2inch color LCD

New Original KEYENCE SL-V80HM Light Curtain Safety Sensor

Model SL-V80HM
Detection capability ø0.98″ ø25 mm
Beam axis spacing/Lens diameter 20 mm/ø5 mm 0.79″/ø0.20″
Effective aperture angle Max. ±2.5 ° (When operating distance is 3 m 98.23′ or more)
Working distance 0.1 to 7 m
Response time (ms) ON→OFF 16.9
OFF→ON 56.9
Light source Infrared LED (850 nm)
Operation mode Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

New Original KEYENCE PJ-50A Light Curtain Safety Sensor

Model PJ-50A
No. of beam axes 4
Beam axis spacing 40 mm 1.57″
Maximum optical axis number 28 optical axes (PJ-50A x 1 + PJ-55A x 12)
Detection area 120 mm 4.72″ (4 optical axes) to 1080 mm 42.52″ (28 optical axes)
Detecting distance 5 m 16.40′
Detectable object Opaque materials (50 mm dia. min.)
Light source Infrared LED
Indicator lamp Output (PJ-50AR)/Power (PJ-50AT) : Red LED, Stable operation (PJ-50AR) : Green LED
Response time 15 ms or less